Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

Chapter 4 139
Programming Command Cross Reference
MANUAL TEST Screens
4. Programming Command
Cross Reference
Measuring Screens
The following commands are used to set the controls and parameters associated
with the Measuring screen.
Table 4-10 Command Cross Reference for Measuring Screen
Item Command
BS Call TESTs:MANual:MEASure:BSCall
BS Level TESTs:MANual:MEASure:AMPLitude <int>
TESTs:MANual:MEASure:AMPLitude?
BS Release TESTs:MANual:MEASure:BSRelease
DC Power Voltage TESTs:MANual:MEASure:DCPower:VOLT <real>
TESTs:MANual:MEASure:DCPower:VOLT?
End Test
[Option 040 GPRS
mode]
TESTs:MANual:MEASure:END
MS Call TESTs:MANual:MEASure:MSCall
MS Release TESTs:MANual:MEASure:MSRelease
MS Signal
[Option 002]
TESTs:MANual:MEASure:SIGNal BURST|CW
TESTs:MANual:MEASure:SIGNal?
Power Control Level TESTs:MANual:MEASure:PLEVel <int>
TESTs:MANual:MEASure:PLEVel?
Signaling State
a
TESTs:MANual:MEASure:SIGNaling:STATe?
Slot Configuration
[Option 040]
TESTs:MANual:MEASure:SCONfigure 1×1|2×1
Timing Advance TESTs:MANual:MEASure:TADVance <int>
TESTs:MANual:MEASure:TADVance?
Traffic Channel
b
TESTs:MANual:MEASure:TCH:CHANnel <int>
TESTs:MANual:MEASure:TCH:CHANnel?
Traffic Channel
Frequency
b
TESTs:MANual:MEASure:TCH:FREQuency <real>
TESTs:MANual:MEASure:TCH:FREQuency?
a. Idle or Attached will be returned when the GPRS mode is selected on the Test Set with
Option 040.
b. Changes to PDTCH (Packet Data Traffic CHannel) when the GPRS mode is selected
on the Test Set with Option 040.