Specifications

Table Of Contents
110 Chapter 3
Programming Command Reference
TESTs Subsystem for MANUAL TEST
Command Reference for Stand-by Screens
These commands are used to set the controls and parameters associated with an
initial test condition.
Send the "DISPlay:MANual:STBY" command to display the Stand-by screen of
the MANUAL TEST for Test Sets without Option 002 and/or Option 040 before
sending the following commands.
For Test Sets with Option 002, send the
"DISPlay:MANual:SYNChronous:STBY" command to display the Stand-by
screen for MANUAL TEST synchronous mode, or the
"DISPlay:MANual:ASYNchronous:STBY" command for MANUAL TEST
asynchronous mode, before sending the following commands.
For Test Sets with Option 040, send the
"DISPlay:MANual:SYNChronous:STBY" command to display the Stand-by
screen for MANUAL TEST synchronous mode, or the
"DISPlay:MANual:GPRS:STBY" command for MANUAL TEST GPRS mode,
before sending the following commands.
BCCH Channel
TESTs:MANual:BCCH:CHANnel <int>
TESTs:MANual:BCCH:CHANnel?
This command specifies the number of Broadcast Control Channel for each radio
standard set by the Radio Format commands. The allowable range and preset
values are as follows:
DCS1800 GSM900 1710200000 to 1784800000;
890200000 to 914800000
1710200000
E-GSM 1710200000 to 1784800000;
880200000 to 914800000
OFF 1710200000 to 1784800000
PCS1900 OFF 1850200000 to 1909800000 1850200000
RFORmat MBANd Allowable Range [Hz] Preset Value [Hz]
RFORmat Allowable Range Preset Value
GSM900 1 to 124 20
E-GSM 0 to 124, 975 to 1023 20
DCS1800 512 to 885 698
PCS1900 512 to 810 698