Specifications
Table Of Contents
- E6392-90042.pdf
- E6392-90042_manual
- Front Matter
- Contents
- 1 Preparing for Use
- 2 Programming Command Guidelines
- 3 Programming Command Reference
- IEEE Common Command
- CONFigure Subsystem
- DISPlay Subsystem
- HCOPy Subsystem
- RFGenerator Subsystem
- SMONitor Subsystem
- SYSTem Subsystem
- TESTs Subsystem for AUTOMATIC TEST
- All Tests Results
- All Tests Results
- Command Reference for Burst Timing/Power Ramp Measurement Screen
- Command Reference for DC Current Measurement Screen
- Command Reference for MS Information
- Command Reference for Peak TX Power Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Stand-by/Measuring Screens
- TESTs Subsystem for MANUAL TEST
- Command Reference for DC Current Measurement Screen
- Command Reference for Measuring Screens
- Command Reference for MS Information
- Command Reference for Peak TX Power /Burst Timing/Power Ramp Measurement Screen
- Command Reference for Phase/Frequency Error Measurement Screen
- Command Reference for Sensitivity/RX Quality/RX Level Measurement Screen
- Command Reference for Spectrum Monitor Measurement Screen
- Command Reference for Stand-by Screens
- TRIGger Subsystem
- 4 Programming Command Cross Reference
- 5 Example Programs
- A Syntax Diagram
- B Command Difference between E6392A & E6392B
- Index

106 Chapter 3
Programming Command Reference
TESTs Subsystem for MANUAL TEST
This command specifies the frequency of Traffic Channel (TCH) to be tested, for
each of the radio standards in conjunction with the Multi Band settings. The
allowable range and preset values are as follows:
Command Reference for Spectrum Monitor Measurement Screen
The SMONitor commands are used to set the controls and parameters associated
with the Spectrum Monitor measurements and the pass/fail tests.
Send the "DISPlay:MANual:SMONitor" command to display the Spectrum
Monitor screen for MANUAL TEST before sending the following commands.
Averaging Function
TESTs:MANual:SMONitor:AVERage OFF|<int>
TESTs:MANual:SMONitor:AVERage?
This command defines whether or not to activate the averaging function. The
choices are OFF and <int> for averaging time. The allowable range is from 2 to 99.
At preset, this is set to OFF.
BS Level
TESTs:MANual:SMONitor:AMPLitude <real> [dBm]
TESTs:MANual:SMONitor:AMPLitude?
This command specifies an amplitude of BS Level. The allowable range is from
−110.0 to −50.0 (dBm) in 0.5 steps. At preset, this is set to −50.0 (dBm).
RFORmat MBANd Allowable Range [Hz] Preset Value [Hz]
GSM900 DCS1800 890200000 to 914800000;
1710200000 to 1784800000
896000000
OFF 890200000 to 914800000
E-GSM DCS1800 880200000 to 914800000;
1710200000 to 1784800000
896000000
OFF 880200000 to 914800000
DCS1800 GSM900 1710200000 to 1784800000;
890200000 to 914800000
1710200000
E-GSM 1710200000 to 1784800000;
880200000 to 914800000
OFF 1710200000 to 1784800000
PCS1900 OFF 1850200000 to 1909800000 1850200000