Specifications

Table Of Contents
Chapter 3 105
Programming Command Reference
TESTs Subsystem for MANUAL TEST
3. Programming Command
Reference
<string 3> (5 digits) and <string 4> (5 digits) are the measured Sensitivity BER
and BLER data ranging from 00.00 to 99.99 in %. If any measurement is
overranged, underranged or not made, the value 99.99 is returned.
NOTE If the mode is set to SYNC on the Test Set with Option 040, refer to
Sensitivity BER and FER Measurement (SYNC mode).
Sensitivity Test Frames
TESTs:MANual:SENSitivity:FRAMe <int>
TESTs:MANual:SENSitivity:FRAMe?
This command specifies the number of test frames. The allowable range is from 1
to 13000 (frames) in 1 frame steps. At preset, this is set to 10 (frames).
Traffic Channel
TESTs:MANual:SENSitivity:CHANnel <int>
TESTs:MANual:SENSitivity:CHANnel?
This command specifies the channel number of Traffic Channel (TCH) to be
tested, for each of the radio standards in conjunction with the Multi Band settings.
The allowable range and preset values are as follows:
Traffic Channel Frequency
TESTs:MANual:SENSitivity:FREQuency
<real> [HZ|KHZ|MHZ|MAHZ]
TESTs:MANual:SENSitivity:FREQuency?
RFORmat MBANd Allowable Range Preset Value
GSM900 DCS1800 1 to 124; 512 to 885 1
OFF 1 to 124
E-GSM DCS1800 0 to 124|975 to 1023;
512 to 885
1
OFF 0 to 124|975 to 1023
DCS1800 GSM900 512 to 885;
1 to 124
512
E-GSM 512 to 885;
975 to 1023|0 to 124
OFF 512 to 885
PCS1900 OFF 512 to 810 512