User manual

Using Load Cards and Loads 5
E6198B Switch/Load Unit User Manual 5-25
Using the Agilent E6176A 16-Channel Load Card
A block diagram of the Agilent E6176A 16-Channel
High-Current Load Card is shown in Figure 5-17. The load card
layout is shown in Figure 5-18. The single-slot design offers high
load density for high-current loads where current transducers
and bridge drive configurations are not required.
The card is one slot wide. “Card Location Recommendations"
The card type is 02
h
. “Load Card Type and Configuration ID"
The factory default configuration is explained in “Selecting a
Power Supply Configuration".
The factory default is to load a 0.05Ω, 0.1% Isense resistor in
each channel. “Selecting a Current-Sense Resistor Value"
The flyback protection is connected from both the normally
open (NO) and normally closed (NC) power switch
connections. “Selecting and Loading Flyback Protection"
Loads are mounted externally and interface to the card using
two load connectors, J1 and J2. “Connecting Loads"