User manual

Register Definitions B
E6198B Switch/Load Unit User Manual B-55
Write Only
State:
1 = closed
0 = open
Power On/Reset State = 0
Power Select 1-16 (W) Base + 12
h
This register controls the Pull Up/Down Power Select armature
relays for channels 1-16. Each bit controls power shared by two
channels. These relays are Form C and the register uses positive
logic: 1 = NO shorted to COM, NC is open; 0 = NC shorted to
COM, NO is open. The power buses selected are determined by
how the card is configured. Writing to this register starts the
relay timer.
Write Only
State: 1 = NO, shorted to Pwr node
State: 0 = NC, shorted to Pwr node
Power On/Reset State = 0 (all channels connected to NC)
Power Select 17-32 (W) Base + 13
h
This register controls the Pull Up/Down Power Select armature
relays for channels 17-32. Each bit controls power shared by two
channels. These relays are Form C and the register uses positive
logic: 1 = NO shorted to COM, NC is open; 0 = NC shorted to
COM, NO is open. The power buses selected are determined by
how the card is configured. Writing to this register starts the
relay timer.
Write Only
Bit 76543 210
Purpose
Pwr15-16 Pwr13-14 Pwr11-12 Pwr9-10 Pwr7-8 Pwr5-6 Pwr3-4 Pwr1-2
Setting state state state state state state state state
Bit 76543 210
Purpose
Pwr31-32 Pwr29-30 Pwr27-28 Pwr25-26 Pwr23-24 Pwr21-22 Pwr19-20 Pwr17-18
Setting state state state state state state state state