Technical data
Programming With TestExec SL 3
E6198B Switch/Load Unit Software Manual 3-5
Example of a Switch/Load Unit Wiring Configuration Values
Tab le 3 -2 Typical configuration values. The configurations are generated when selecting the “Generate Wire and
Aliases” checkbox.
Name Value Description
ICA Slot 1 The designation for the ICA connector type or slot number to which
the load cards are to be wired. For the Test System Interface ICA
type, the designations are: "TC" (Test Connector), "Agilent" (High
Power), or "CC" (Custom Connector). For the Mass Interconnect ICA
type, the slot number designations are: 1 to 21 (i.e., slot numbers of
the Mass Interconnect).
For the L2000 Interconnect ICA type, the slot number designations
are: 1 to 26 (i.e. slot numbers of the L2000 Interconnect).
Connector 1 The connector number for the Test System Interface ICA type are
either 1 or 2. The connector number for the Mass Interconnect ICA
type are either A or B.
The connector number for the L2000 Interconnect ICA type is only
A.
Starting Pin 2 For the Test System Interface ICA type, the starting pin number for
the TCx connector may be "K1" where "K" is the Row value and "1" is
the column value; other connectors have different values. This field
is usually grayed out since these values are already set by the values
in the selected System Database Files.