Specifications

4-76 TS-8900 Functional Test System Diagnostics User Guide
4 Diagnostic Testing Details
CEDGN_RS232.tpa (RS232 Serial COM CEDGN Test Flow)
The testsplan supports testing of four RS232 COM ports. It is a
loopback test where Tx and Rx of the COM port is connected
together.
User is required to set the variables to reflect the system under
test.
1 = present, 0 = not present
bCOM1 = 1st COM Port
bCOM2 = 2nd COM Port
bCOM3 = 3rd COM Port
bCOM4 = 4th COM Port
Device that user sets as not present will not be tested. The test
starts by performing:
COM1 on TC1 Tests
Display instruction to Install CEDGN Board #1 on TC1.
Use COM1 to transmit characters “This is test com1”.
Use COM1 to receive and compare to ensure the received
characters matches the transmitted characters.
COM2 on TC3 Tests
Display instruction to Install CEDGN Board #1 on TC3.
Use COM2 to transmit characters “This is test com2”.
Use COM2 to receive and compare to ensure the received
characters matches the transmitted characters.
COM3 on TC5 Tests
Display instruction to Install CEDGN Board #1 on TC5.
Use COM3 to transmit characters “This is test com3”.
Use COM3 to receive and compare to ensure the received
characters matches the transmitted characters.
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com