Specifications

4-74 TS-8900 Functional Test System Diagnostics User Guide
4 Diagnostic Testing Details
M9216A DAQ4 Tests
Display instruction to install CEDGN Board #1 on TC1 and CEDGN
Board #5 on appropriate TC. OPEN all 16 actuators on switch S1
and S2 of Board #5. Install Cable E6170-61607 from J1 of Board #1
to J1 of Board #5.
Setup SLU internal DAC1 to output 5V.
Route 5V from DAC1 to individual DAQ channel and use DAQ to
measure each channel.DAC1 EarthGnd is connected to DAQ
ground via UUTCommon of PinMatrix.
Test cov ers :
DAQ4 1A (via Row1)
DAQ4 1B (via Row2)
DAQ4 1C (via Row3)
DAQ4 1D (via Row4)
DAQ4 2A (via Row5)
DAQ4 2B (via Row6)
DAQ4 2C (via Row7)
DAQ4 2D (via Row8)
DAQ4 3A (via Row9)
DAQ4 3B (via Row10)
DAQ4 3C (via Row11)
DAQ4 3D (via Row12)
DAQ4 4A (via Row13)
DAQ4 4B (via Row14)
DAQ4 4C (via Row15)
DAQ4 4D (via Row16)
DAQ4 5A (via Row17)
DAQ4 5B (via Row18)
DAQ4 5C (via Row19)
DAQ4 5D (via Row20)
DAQ4 6A (via Row21)
DAQ4 6B (via Row22)
DAQ4 6C (via Row23)
DAQ4 6D (via Row24)
DAQ4 7A (via Row25)
DAQ4 7B (via Row26)
DAQ4 7C (via Row27)
DAQ4 7D (via Row28)
DAQ4 8A (via Row29)
DAQ4 8B (via Row30)
DAQ4 8C (via Row31)
DAQ4 8D (via Row32)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com