Specifications

Diagnostic Testing Details 4
TS-8900 Functional Test System Diagnostics User Guide 4-71
M9216A DAQ1 Tests
Display instruction to install CEDGN Board #1 on TC1 and CEDGN Board #5 on appropriate TC. OPEN all
16 actuators on switch S1 and S2 of Board #5. Install Cable E6170-61607 from J1 of Board #1 to J1 of
Board #5.
Setup SLU internal DAC1 to output 5V.
Route 5V from DAC1 to individual DAQ channel and use DAQ to measure each channel.DAC1 EarthGnd is
connected to DAQ ground via UUTCommon of PinMatrix.
Test c ov e rs :
DAQ1 1A (via Row1)
DAQ1 1B (via Row2)
DAQ1 1C (via Row3)
DAQ1 1D (via Row4)
DAQ1 2A (via Row5)
DAQ1 2B (via Row6)
DAQ1 2C (via Row7)
DAQ1 2D (via Row8)
DAQ1 3A (via Row9)
DAQ1 3B (via Row10)
DAQ1 3C (via Row11)
DAQ1 3D (via Row12)
DAQ1 4A (via Row13)
DAQ1 4B (via Row14)
DAQ1 4C (via Row15)
DAQ1 4D (via Row16)
DAQ1 5A (via Row17)
DAQ1 5B (via Row18)
DAQ1 5C (via Row19)
DAQ1 5D (via Row20)
DAQ1 6A (via Row21)
DAQ1 6B (via Row22)
DAQ1 6C (via Row23)
DAQ1 6D (via Row24)
DAQ1 7A (via Row25)
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com