Specifications
58 Planning System Testplans Chapter 3
Agilent TS-5400
Fixturing
Worksheet
While completing the Agilent TS-5400 Fixturing Worksheet, remember that
this worksheet will be used to build the fixture. It is important to be
consistent in your naming conventions and the way that information is
entered in the form. Suggestions are given in the descriptions of the
worksheet columns. You can also refer to “Wiring the Fixture” later in this
chapter.
Figure 3-4 shows the Agilent Fixturing Worksheet. Each section of the
worksheet is described below.
Note The worksheet is for a system using the Mass Interconnect. Systems using
the Test System Interface is similar, but with different connector numbers
and with no “Expander Blocks”.
Fixture Table - UUT
Connections
This section describes the connections that will be made to the UUT.
UUT Pin # - the physical name of each connection to the UUT. They should
be listed in order making sure not to skip any pins, including pins which are
not connected. The typical format for the UUT pin number is J1-1. This
corresponds to Jack 1-pin 1. You should leave several lines between each
entry to allow for multiple resource allocation entries.
Figure 3-4. Example Agilent TS-5400 Fixturing Worksheet
Artisan Technology Group - Quality Instrumentation ... Guaranteed | (888) 88-SOURCE | www.artisantg.com