Test Description: In the test description section, briefly describe the test to
be performed.
Measurements: Under measurements, describe what pin on the Unit Under
Test (UUT) will be measured, the expected measurement, and what the test
limits are. The Agilent TestExec SL software allows multiple results to be
limits checked.
Preconditions: For the Unit Under Test, use the preconditions section to
describe the state the UUT must be in before performing the measurement
as well as how to set it to the desired state. For power, describe what power
connections are required for this test. Under the loads portion of the
preconditions section, describe what loads, if any, are required to perform
the test.
Constraints: Under constraints give information on timing constraints such
as settling time before a measurement is valid, as well as test order
constraints such as making sure the serial interface has been tested before
using it to set up the UUT in this test.
Reuse: To complete the reuse area, use the test executive's Action Libraries
box and Test Libraries box to find actions and tests, respectively, that can be
reused.
Figure 3-1. Sample Agilent TS-5400 Test Description Worksheet