Specifications

30 How to Use the System Software Chapter 2
Agilent E1411B Digital
Multimeter
An instrument box which connects to the Agilent E6171 Measurement
Control Module, such as the Agilent E1411 DMM, usually has two different
dialog boxes which depend on the type of path selected (as shown in Agilent
E1411 DMM Debug Front Panel (showing Path Selection)A and Agilent
E1411 DMM Debug Front Panel (showing Path Selection)B). This allows
you to either connect to the pin on the UUT (Agilent E1411 DMM Debug
Front Panel (showing Path Selection)A) or select any point within the
system by defining a custom switching path (Agilent E1411 DMM Debug
Front Panel (showing Path Selection)B). The custom switching is applied on
top of the current switching state, so to undo a switching path you need to
define a ‘disconnect’ path.
The debug panel boxes and buttons do the following:
Function:
Choose ACV, DCV, Ohms, Ohms - Offset Compensated
The measurement is made in auto range and medium resolution.
Switching Path:
The debug panel supports the selection of the switching path. The
panel switches both high and low connections of voltage sense and the
high and low connection of the current terminals. The sense
connections are connected in parallel with the high and low terminals.
You specify the high or low terminal and the system automatically
connects the associated sense terminal.
Measurement Results:
Press the “Single” button to initiate a single measurement; press the
“Continuous” button to initiate a series of measurements. The
continuous button is modified to a “Stop” button once pressed. When
the dialog box is brought up, the measurement results box is blank.
Switching Action Editor:
This button enables the editor to select the switching paths for the
Figure 2-12. Agilent E1411 DMM Debug Front Panel (showing Path Selection)
A
B
B