Specifications

7
Seamless oscilloscope
integration with View Scope
Easily make time-correlated
measurements between Agilent
logic analyzers and oscilloscopes.
The time-correlated logic analyzer
and oscilloscope waveforms are
integrated into a single logic analyzer
waveform display for easy viewing
and analysis. You can also trigger the
oscilloscope from the logic analyzer
(or vice versa), automatically de-skew
the waveforms and maintain marker
tracking between the two instru-
ments. View Scope allows you to per-
form the following more effectively:
• Validate signal integrity
• Track down problems caused by
signal integrity
• Validate correct operation of A/D
and D/A converters
• Validate correct logical and timing
relationships between the analog
and digital portions of a design
Connection
The Agilent logic analyzer and
oscilloscope can be physically
connected with standard BNC and
LAN connections. Two BNC cables
are connected for cross triggering,
and the LAN connection is used to
transfer data between the instru-
ments. The View Scope correlation
software is standard in the logic
analyzer’s application software
version 3.50 or higher. The View
Scope software includes:
• Ability to import some or all of the
captured oscilloscope waveforms
• Auto scaling of the scope wave-
forms for the best fit in the logic
analyzer display
Feature Benefit
Automated setup Quickly get to your first measurement using
the logic analyzer’s Help wizard for easy
setup, regardless of which supported Agilent
oscilloscope you connect to.
Integrated waveform display Instantly validate the logical and timing
relationships between the analog and digital
portions of your design. View oscilloscope and
logic analyzer waveforms integrated into a
single logic analyzer waveform display.
Automatic measurement de-skew Save time and gain confidence in measurement
results with measurements that are
automatically de-skewed in time.
Cross trigger the logic analyzer and
oscilloscope
Start your debug approach from either the
analog or digital domain with the flexibility to
trigger the oscilloscope from the logic analyzer
(or vice versa).
Tracking markers Precisely relate information on the
oscilloscope’s display to the corresponding
point in time on the logic analyzer display with
tracking markers. The oscilloscope’s time
markers automatically track adjustments of the
logic analyzer’s global markers.
Unleash the Complementary Power of a Logic Analyzer and an Oscilloscope
Figure 3. View Scope seamlessly integrates your scope and logic analyzer waveforms into
a single display.