Agilent 16850 Series Portable Logic Analyzers Data Sheet The industry’s fastest timing capture with deep memory ― for fast digital system debug • 2.5 GHz timing capture with up to 128 M sample memory for finding elusive problems quickly, even far from the trigger point • Up to 1.
16850 Series Portable Logic Analyzer Selection Guide • 80 ps resolution (12.5 GHz) Timing Zoom with 256 K samples allows you to observe signal timing in proximity to the trigger point • Up to 1.
Industry’s Fastest Timing Capture with Deep Memory ― for Fast Digital System Debug Agilent 16850 Series portable logic analyzers offer the highest performance, with deep, high speed timing and state measurements, combined with the applications and usability your digital development teams need to debug their modern systems ― and at a great price. Figure 1.
Eye Scan to Set Sample Points and to View Signal Integrity Automate measurement setup and quickly gain diagnostic clues 16850 Series logic analyzers make it easy for you to get up and running quickly by automating your measurement setup process. In addition, the logic analyzer’s setup/hold window (or sampling position) and threshold voltage settings are automatically determined so you can capture data on high-speed buses with the highest accuracy. Auto Threshold and Sample Position mode allow you to...
16850 Series Logic Analyzer Specifications and Characteristics Number of channels 16851A 34 (1 clock + 1 clock qualifier) 16852A 68 ( 1 clock + 3 clock qualifiers) Deep timing (asynchronous) sampling mode 16853A 102 (1 clock + 3 clock qualifiers) 16854A 136 (1 clock + 3 clock qualifiers) Conventional and transitional timing (up to 128 M depth) Maximum sample rate in full channel mode (nom) Maximum sample rate in half channel mode (nom) Sample period on all channels (nom) Sample period in half ch
16850 Series Logic Analyzer Specifications and Characteristics (continued) Trigger characteristics (conventional timing, transitional timing, and state sampling modes) Maximum trigger sequence speed (standard) (nom) Maximum trigger sequence speed (option 700) (nom) Maximum trigger sequence levels (nom) Trigger sequence level branching (nom) Trigger position (nom) Trigger resources (nom) Maximum occurrence counter (nom) Maximum pattern width (nom) Maximum range width (nom) Timers range (nom) Timer resolutio
Unleash the Complementary Power of a Logic Analyzer and an Oscilloscope Seamless oscilloscope integration with View Scope Easily make time-correlated measurements between Agilent logic analyzers and oscilloscopes. The time-correlated logic analyzer and oscilloscope waveforms are integrated into a single logic analyzer waveform display for easy viewing and analysis.
Get Instant Insight into your Design with Multiple Views and Analysis Tools Acquisition and analysis tools provide rapid insight into your toughest debug problems When you want to understand what your target is doing and why, you need acquisition and analysis tools that rapidly consolidate data and provide insight into your system’s behavior. Figure 4.
Validate your DDR2 and DDR3 Memory Systems The state analysis capabilities of the 16850 Series allow it to make measurements and analysis on DDR2 and DDR3 memories up to DDR2/3 1333 (667 MHz clock) on address and control lines. Memory bus decode, compliance testing, and performance analysis are available in state mode only with related orderable tools. Addr/Cmd only DDR2 memory DDR3 memory Up to DDR2 1333 (667 MHz clock) state measurements on Addr/Cmd only.
Validate your DDR2 and DDR3 Memory Systems (continued) 16850 Series capture and decode of DDR3 Addr/Cmd lines Performance test analysis of DDR3 Addr/Cmd line saved trace Compliance test analysis of DDR3 Addr/Cmd line saved trace Figure 5. Multiple views for DDR2 and DDR3 Addr/Cmd capture.
Deep memory capture with 2.5 GHz (400 ps resolution) timing Figure 6. Timing mode capture with 400 ps resolution and up to 128 M samples memory depth (example capture at –500 μs before trigger). Powerful, customizable triggering with a 1.4 GHz sequencer Figure 7. Example of a time out trigger to capture an error condition.
16850 Series Instrument Characteristics Standard data views Waveform Listing Compare Source code Eye scan Data display Numeric bases for data display Integrated display of data as digital waveforms, analog waveforms imported from an external oscilloscope, and/or as a chart of a bus’ values over time Displays data as a state listing Compares data from different acquisitions and highlights differences Displays time-correlated source code and inverse assembly simultaneously in a split display Define the t
16850 Series Instrument Characteristics (continued) 16850 Series PC characteristics Operating system Processor Chipset System memory Removable Hard disk drive Installed on hard drive Microsoft Windows® 7 Embedded (64-bit) Core 2 Duo, M890, 3.
16850 Series Interfaces Peripheral interfaces Display Keyboard Mouse Serial PCI card expansion slot Audio ports USB One 15-pin XGA connector and one DVI connector PS/2 PS/2 9-pin D-sub 1 full profile Line in, line out, mic in Six 2.
16850 Series Physical Characteristics Power 16851A 16852A 16853A 16854A Add 1.25 inches to the width to account for probes that plug into the right side of instrument 443.23 (17.45) Dimensions 100 to 240V ± 10 %, 50/60Hz, 400 W max 100 to 240V ± 10 %, 50/60Hz, 400 W max 100 to 240V ± 10 %, 50/60Hz, 400 W max 100 to 240V ± 10 %, 50/60Hz, 400 W max 292.2 (11.53) Note: • The mains supply voltage fluctuations are not to exceed ± 10 % of the nominal supply voltage. • Add 1.
Ordering Information Each 16850 Series portable logic analyzer comes with one USB keyboard, one USB mouse, accessory pouch, power cord and 3-year warranty standard. Selecting a logic analyzer to meet your application and budget is as easy as 1, 2, 3. Choose the channel count Model 16851A 1 Channels 2 34 16853A 68 102 16854A 136 Choose the state speed State speeds 3 16852A 350 MHz state clock; 700 Mbps data rate: Standard 700 MHz state clock; 1.
Additional 16850 Series Options Agilent product or option number Description E5864A Additional external hard drive (imaged with operating system and logic analyzer application software) Ordering information E5864A After Purchase Options Upgrade memory depth or state speed after purchase Logic analyzer channels Logic analyzer models After purchase upgrade model numbers Memory depth (samples) State speed 34 16851A 16851AU 68 102 136 16852A 16853A 16854A 16852AU 16853AU 16854AU 4 M: < Upgrade model numbe
www.agilent.com www.agilent.com/find/16850-Series myAgilent myAgilent www.agilent.com/find/myagilent A personalized view into the information most relevant to you. www.axiestandard.org AdvancedTCA® Extensions for Instrumentation and Test (AXIe) is an open standard that extends the AdvancedTCA for general purpose and semiconductor test. Agilent is a founding member of the AXIe consortium. Three-Year Warranty www.agilent.