User`s guide

26 Users Guide
Signal Studio for WiMAX E4438C Option H13
WiMAX Project Parameters
Preamble View
Figure 13 Preamble View
In the Preamble View, the following parameters are shown:
Table 2 Preamble Parameters
Item Range Default Description
Burst Type Preamble Preamble Shows the type of burst (fixed value)
Preamble
Type
Long
Preamble |
Short
Preamble
Long
Preamble
This appears only for the downlink. Select the
preamble type.
OFDM
Symbol
Length
1 | 2 2 for
Downlink, 1
for Uplink
This is a read-only parameter. If 'Long
Preamble' is selected on the 'Preamble Type',
this value is '2'. For 'Short Preamble' the value
is '1'.