User`s guide
Table Of Contents
- Agilent E3632A DC Power Supply
- Table of Contents
- List of Figures
- List of Tables
- 1 Getting Started
- 2 Operation and Features
- Overview
- Constant Voltage Operation
- Constant Current Operation
- Storing and Recalling Operating States
- Programming the Overvoltage Protection
- Programming the Overcurrent Protection
- Remote Voltage Sensing
- Disabling the Output
- System-Related Operations
- Remote Interface Configuration
- GPIB Interface Configuration
- RS-232 Interface Configuration
- Calibration
- 3 Remote Interface Reference
- SCPI Command Summary
- Introduction to the SCPI Language
- Simplified Programming Overview
- Using the APPLy Command
- Output Settings and Operation Commands
- Triggering Commands
- System-Related Commands
- Calibration Commands
- RS-232 Interface Commands
- SCPI Status Registers
- What is an event register?
- What is an enable register?
- SCPI status system
- The Questionable Status register
- The Standard Event register
- The Status Byte register
- Using Service Request (SRQ) and Serial POLL
- Using *STB? to read the Status Byte
- Using the Message Available Bit (MAV)
- To interrupt your bus controller using SRQ
- To determine when a command sequence is completed
- Using *OPC to signal when data is in the output buffer
- Status Reporting Commands
- Halting an Output in Progress
- SCPI Conformance Information
- IEEE-488 Conformance Information
- 4 Error Messages
- 5 Application Programs
- 6 Tutorial
- 7 Characteristics and Specifications

1Getting Started
Product at a Glance
22 E3632A User’s Guide
Display annunciators
Figure 1-5 Display annunciators
NOTE
Use the front-panel key to:
• Select the GPIB or RS-232 interface (see Chapter 2).
• Set the GPIB bus address (see Chapter 2).
• Set the RS-232 baud rate and parity (see Chapter 2).
I/O Config
Table 1 - 5 Display annunciators overview
Item Description
Adrs The power supply is addressed to listen or talk over a remote interface.
Rmt The power supply is in the remote interface mode.
15 V Shows the 15 V/7 A range is selected.
30 V Shows the 30 V/4 A range is selected.
OVP The overvoltage protection function is enabled when the annunciator turns on or the overvoltage
protection circuit has caused the power supply to shut down when the annunciator flashes.
OCP The overcurrent protection function is enabled when the annunciator turns on or the overcurrent
protection circuit has caused the power supply to shut down when the annunciator flashes.
CAL The power supply is in the calibration mode.
Limit The display shows the limit values of the voltage and current.