User`s guide
Table Of Contents
- Agilent E3632A DC Power Supply
- Table of Contents
- List of Figures
- List of Tables
- 1 Getting Started
- 2 Operation and Features
- Overview
- Constant Voltage Operation
- Constant Current Operation
- Storing and Recalling Operating States
- Programming the Overvoltage Protection
- Programming the Overcurrent Protection
- Remote Voltage Sensing
- Disabling the Output
- System-Related Operations
- Remote Interface Configuration
- GPIB Interface Configuration
- RS-232 Interface Configuration
- Calibration
- 3 Remote Interface Reference
- SCPI Command Summary
- Introduction to the SCPI Language
- Simplified Programming Overview
- Using the APPLy Command
- Output Settings and Operation Commands
- Triggering Commands
- System-Related Commands
- Calibration Commands
- RS-232 Interface Commands
- SCPI Status Registers
- What is an event register?
- What is an enable register?
- SCPI status system
- The Questionable Status register
- The Standard Event register
- The Status Byte register
- Using Service Request (SRQ) and Serial POLL
- Using *STB? to read the Status Byte
- Using the Message Available Bit (MAV)
- To interrupt your bus controller using SRQ
- To determine when a command sequence is completed
- Using *OPC to signal when data is in the output buffer
- Status Reporting Commands
- Halting an Output in Progress
- SCPI Conformance Information
- IEEE-488 Conformance Information
- 4 Error Messages
- 5 Application Programs
- 6 Tutorial
- 7 Characteristics and Specifications
Remote Interface Reference 3
Triggering Commands
E3632A User’s Guide 95
Triggering commands
INITiate
Cause the trigger system to initiate. This command
completes one full trigger cycle when the trigger source is an
immediate and initiates the trigger subsystem when the
trigger source is bus.
TRIGger:DELay {<seconds>|MINimum|MAXimum}
Set the time delay between the detection of an event on the
specified trigger source and the start of any corresponding
trigger action on the power supply output. Select from 0 to
3600 seconds. MIN = 0 seconds. MAX = 3600 seconds. At
*RST, this value is set to 0 seconds.
TRIGger:DELay? [MINimum|MAXimum]
This query returns the trigger delay.
TRIGger:SOURce {BUS|IMMediate}
Select the source from which the power supply will accept a
trigger. The power supply will accept a bus (software) trigger
or an internal immediate trigger. At *RST, the bus trigger
source is selected.
TRIGger:SOURce?
This query returns the present trigger source. Returns BUS
or IMM.
*TRG
Generate a trigger to the trigger subsystem that has selected
a bus (software) trigger as its source (TRIG:SOUR BUS). The
command has the same effect as the Group Execute Trigger
(GET) command. For RS- 232 operation, make sure the power
supply is in the remote interface mode by sending the
SYST:REM command first.