User`s guide

Table Of Contents
3 Remote Interface Reference
Output Settings and Operation Commands
92 E3632A User’s Guide
VOLTage:RANGe {P15V|P30V||LOW|HIGH}
This command selects an output range to be programmed by
the identifier. When 15 V/7 A range is selected, the
maximum programmable voltage and current are limited to
15.45 V and 7.21 A. When 30 V/4 A range is selected, the
maximum programmable voltage and current are limited to
30.90 V and 4.12 A. P30V or HIGH is the identifier for the
0 V/4 A range and P15V or LOW is for the 15 V/7 A range.
At *RST, the 15 V/7 A range is selected.
VOLTage:RANGe?
This query returns the currently selected range. The
returned parameter is P30V (HIGH) or P15V (LOW).
MEASure:CURRent?
This query returns the current measured across the current
sense resistor inside the power supply.
MEASure[:VOLTage]?
This query returns the voltage measured at the sense
terminals of the power supply.