Table of corresponding 4291B vs. E4991A GPIB commands
Table of Corresponding GPIB Commands
D. Table of corresponding
4291B vs. E4991A GPIB
commands
Sets the frequency span. SENS:FREQ:SPAN FREQ:SPAN on page 377
Sets the frequency span value of the difference between
the marker and the delta marker values.
CALC{1-5}:MARK:SET on page 336
Sets the frequency span value of the "frequency span ×
zooming aperture".
None (No zooming function for sweep
span.)
Sets the start frequency value. SENS:FREQ:STAR FREQ:STAR on page 378
Sets the start frequency value of the sweep parameter
value of the marker.
CALC{1-5}:MARK:SET on page 336
Sets the stop frequency value. SENS:FREQ:STOP FREQ:STOP on page 379
Sets the stop frequency value of the sweep parameter
value of the marker.
CALC{1-5}:MARK:SET on page 336
Clears the entire list. SENS:LIST:CLE SEGM:DEL:ALL on page 406
Completes editing the frequency sweep list. SENS:LIST:SAVE None (No need to declare.)
Selects the segment to edit. SENS:LIST:SEGM None (Specifies a segment number in
the GPIB command for the segment to
edit.)
Adds a new segment to a list sweep table. SENS:LIST:SEGM:ADD None (SEGM:COUN on page 397
command is used to clear a table and add
a new segment.)
Sets the point averaging factor for the list sweep table. SENS:LIST:SEGM:AVER:COUN SEGM{1-16}:AVER:COUN on
page 396
Sets the OSC level for the list sweep table to Ampere. SENS:LIST:SEGM:CURR SEGM{1-16}:CURR on page 398
Deletes the segments. SENS:LIST:SEGM:DEL None (Only a method to delete all the
segments at once is available.)
Edits the segments. SENS:LIST:SEGM:EDIT None (However, it is necessary to create
a segment in the segment sweep table
using the following command before
editing the segment.)
SEGM:COUN on page 397
Sets to center the frequency value of the segment in the
list sweep table.
SENS:LIST:SEGM:FREQ:CENT SEGM{1-16}:FREQ:CENT on
page 407
Sets the frequency span of the segment. SENS:LIST:SEGM:FREQ:SPAN SEGM{1-16}:FREQ:SPAN on
page 408
Sets the start frequency value of the segment in the list
sweep table.
SENS:LIST:SEGM:FREQ:STAR SEGM{1-16}:FREQ:STAR on
page 409
Sets the start frequency value of the sweep parameter
value of the marker.
None
Sets the stop frequency value of the segment in the list
sweep table.
SENS:LIST:SEGM:FREQ:STOP SEGM{1-16}:FREQ:STOP on
page 410
Sets the stop frequency value of the sweep parameter
value of the marker.
None
Sets the number of points for the segment for the list
sweep table.
SENS:LIST:SEGM:POIN SEGM{1-16}:SWE:POIN on page 413
Sets the OSC level for the list sweep table to dBm. SENS:LIST:SEGM:POW SEGM{1-16}:POW on page 411
Quits editing a segment of the list sweep table. SENS:LIST:SEGM:QUIT None (No need to declare.)
Completes modifying a segment in a list sweep table. SENS:LIST:SEGM:SAVE
Sets the OSC level for a list sweep table with the unit of
Volt.
SENS:LIST:SEGM:VOLT SEGM{1-16}:VOLT on page 414
Defines number of sweeps. SENS:SWE:COUN None (However, if the sweep averaging
function is on, one trigger will perform a
sweep of the specified number of
averagings.)
Defines point delay times. SENS:SWE:DWEL1 SWE:DWEL2 on page 509
4291B feature 4291B GPIB command E4991A GPIB command