Table of corresponding 4291B vs. E4991A GPIB commands
Table of Corresponding GPIB Commands
D. Table of corresponding
4291B vs. E4991A GPIB
commands
Sets the sweep averaging factor for the active channel. SENS:AVER2:COUN CALC:AVER:COUN on page 290
Turns the sweep averaging factor ON or OFF for the
active channel.
SENS:AVER2 CALC:AVER on page 289
Sets the calibration kit. SENS:CORR1:CKIT SENS:CORR1:CKIT on page 420
Defines a label of the user-modified calibration kit. SENS:CORR1:CKIT:LAB None
Stores the user-modified calibration kit into memory. SENS:CORR1:CKIT:SAVE None (However, can save a defined
value in the user-defined calibration kit
in the state file.)
Enters the capacitance value of the OPEN standard that
is used in the user-modified calibration kit.
SENS:CORR1:CKIT:STAN1:C SENS:CORR1:CKIT:STAN1:C on
page 422
Enters the conductance value of the OPEN standard that
is used in the user-modified calibration kit.
SENS:CORR1:CKIT:STAN1:G SENS:CORR1:CKIT:STAN1:G on
page 423
Enters the inductance value of the SHORT standard that
is used in the user-modified calibration kit.
SENS:CORR1:CKIT:STAN2:L SENS:CORR1:CKIT:STAN2:L on
page 426
Enters the resistance value of the SHORT standard that
is used in the user-modified calibration kit.
SENS:CORR1:CKIT:STAN2:R SENS:CORR1:CKIT:STAN2:R on
page 429
Enters the resistance value of the LOAD standard that is
used in the user-modified calibration kit.
SENS:CORR1:CKIT:STAN3:R SENS:CORR1:CKIT:STAN3:R on
page 433
Enters the reactance value of the LOAD standard that is
used in the user-modified calibration kit.
SENS:CORR1:CKIT:STAN3:X SENS:CORR1:CKIT:STAN3:L on
page 430
(However, uses a reactance value for
setting.)
Selects and acquires the calibration. SENS:CORR1:COLL SENS:CORR1:COLL on page 437
Selects the frequency points where the calibration data
is collected.
SENS:CORR1:COLL:FPO SENS:CORR1:COLL:FPO on
page 438
Calculates the error-correction coefficients from the
calibration data and stores the coefficients.
SENS:CORR1:COLL:SAVE SENS:CORR1:COLL:SAVE on
page 439
Sets the port extension ON or OFF. SENS:CORR1:EDEL:STAT Uses the following command to set the
off-set delay time, except for the test
fixture electrical length, and at the same
time sets ON the compensation function.
SENS:CORR2:EDEL:TIME on
page 453
Sets the port extension value. SENS:CORR1:EDEL
Queries to determine if the correction state is ON or
OFF.
SENS:CORR1? SENS:CORR1 on page 419
Defines the label for the user-modified compensation
kit.
SENS:CORR2:CKIT:LAB None
Stores the user-modified compensation kit into memory. SENS:CORR2:CKIT:SAVE None (However, can save the standard
value for the fixture compensation in a
state file.)
Enters the capacitance value of the OPEN standard that
is used in OPEN compensation.
SENS:CORR2:CKIT:STAN1:C SENS:CORR2:CKIT:STAN1:C on
page 441
Enters the conductance value of the OPEN standard that
is used in OPEN compensation.
SENS:CORR2:CKIT:STAN1:G SENS:CORR2:CKIT:STAN1:G on
page 442
Selects the fixture compensation open standard. SENS:CORR2:CKIT:STAN1 SENS:CORR2:CKIT:LIST on
page 440
(However, cannot choose open/short
alone.)
Enters the inductance value of the SHORT standard that
is used in SHORT compensation.
SENS:CORR2:CKIT:STAN2:L SENS:CORR2:CKIT:STAN2:L on
page 445
Enters the resistance value of the SHORT standard that
is used in SHORT compensation.
SENS:CORR2:CKIT:STAN2:R SENS:CORR2:CKIT:STAN2:R on
page 448
4291B feature 4291B GPIB command E4991A GPIB command