Specifications

526 Chapter 17
GPIB Command Reference
TRIG:SLOP
TRIG:SLOP
Format TRIGger[:SEQuence]:SLOPe {POSitive|NEGative}
TRIGger[:SEQuence]:SLOPe?
Description Selects the polarity of the trigger signal that is to be received by the external trigger input
connector, located on the rear panel. When set to positive, a trigger is executed when the
signal changes from a low level to a high level. When set to negative, a trigger is executed
by the opposite signal level change direction.
Parameters
Query response {POS|NEG}<newline><^END>
Front Panel
Equivalents
Trigger - Trigger Setup... - Trigger Polarity: [Negative/Positive]
TRIG:SOUR
Format TRIGger[:SEQuence]:SOURce {INTernal|MANual|EXTernal|BUS}
TRIGger[:SEQuence]:SOURce?
Description Selects the trigger source.
Parameters
Query response {INT|MAN|EXT|BUS}<newline><^END>
Front Panel
Equivalents
Trigger - Trigger Setup... - Trigger Source
Description
POSitive (Default) Specifies positive (trigger is executed when the signal
changes from a low level to a high level).
NEGative Specifies negative (trigger is executed when the signal
changes from a high level to a low level).
Description
INTernal (Default) Specifies an internal trigger.
MANual Specifies a manual trigger (operated by the front panel key).
EXTernal Specifies an external trigger (received by the EXT
TRIGGER connector on the rear panel).
BUS Specifies the GPIB trigger (trigger operated by execution of
*TRG command).