Specifications
480 Chapter 17
GPIB Command Reference
SOUR:VOLT:OFFS
SOUR:VOLT:OFFS
Format SOURce:VOLTage[:LEVel][:IMMediate][:AMPLitude]:OFFSet <numeric>
SOURce:VOLTage[:LEVel][:IMMediate][:AMPLitude]:OFFSet?
Description Sets the dc bias voltage level in the fixed voltage source mode. This command can be used
when Option 001 (dc bias function) is installed.
Parameters
If the specified parameter is outside the range, the minimum (if the lower limit of the range
is exceeded) or maximum value (if the upper limit is exceeded) will be assumed.
Query response {numeric}<newline><^END>
Front Panel
Equivalents
Stimulus - Source... - Bias Level: V
<numeric>
Description dc bias voltage level
Data type Floating point
Range -40 to 40
Default 0
Resolution 1E-3
Unit V (volt)