Relay Matrix Switch Command Reference 41Chapter 3
ARM
The ARM subsystem selects the number of scanning cycles (1 to 32,767)
for each INITiate command.
Subsystem Syntax ARM
:COUNt <number> MIN | MAX
:COUNt? [MIN | MAX]
ARM:COUNt
ARM:COUNt <number> MIN | MAX allows scanning cycles to occur a
multiple of times (1 to 32,767) with one INITiate command when
INITiate:CONTinuous OFF | 0 is set. MIN sets 1 cycle and MAX sets
32,767 cycles.
Parameters
Comments Number of Scans: Use only values between 1 and 32,767 for the number
of scanning cycles.
Related Commands: ABORt, INITiate[:IMMediate]
*RST Condition: ARM:COUNt 1
Example Setting Ten Scanning Cycles
This example sets a Relay Matrix Switch module for 10 scans of
channels 00 through 03.
ARM:COUN 10
!Set 10 scans per INIT command
SCAN (@10000:10003)
!Scan channels 00-03
INIT
!Start scan, close channel 00
Name Type Range of Values Default Value
<number> numeric 1-32,767 | MIN | MAX 1