User`s manual
22 Getting Started Chapter 1
Terminal Module Wiring
Guidelines
User wiring to the Relay Matrix Switch modules is to the High (H) and Low
(L) connections on terminal module. Figure 1-10 gives guidelines to wire the
terminal modules. Maximum terminal wire size is No. 16 AWG. Wire ends
should be stripped 6mm (0.25 in.) and tinned. When wiring all channels,
use a smaller gauge wire (No. 20 - 22 AWG). The expansion connectors
allow you to create larger matrices. See "Creating Larger Matrices".
Figure 1-10. Wiring the Terminal Module
Tighten screw.
Insert wire into terminal.
Screw-Type
Make connections.
Remove clear cover.
3
1
VW1 Flammability
Use wire
Rating
size 16-26
AWG
0.2"
5mm
Tab
and release.
B. Press tab forward
A. Release screws.
Route wiring.4
secure wires.
Tighten wraps to
wire exit panels.
Remove 1 of the 3
Remove and retain wiring exit panel.
2
Cut required
holes in panels
for wire exit
Replace Wiring Exit Panel5
Keep wiring exit panel
hole as small as
possible
B. Press down and
tighten screws
Replace Clear cover
A. Hook in the top cover tabs
onto the fixture
6