*RST Condition: None
Example Querying the A24 Address Space Ready Indication Offset
VINS:VME:REC:ADDR:READ? Queries A24 offset for ready indication.
:IDENtity?
VINStrument:IDENtity? returns a response consisting of 4 fields, indicating the
virtual instrument capability of the Agilent E1445A:
HEWLETT-PACKARD VIRTUAL INSTRUMENT,ANY DTOA,0,A.01.00
The first and last fields indicate that the Agilent E1445A conforms to revision
A.01.00 of Agilent’s Virtual Instrument/Local Bus System Specification. The
second field indicates that the Agilent E1445A is a digital-to-analog converter. The
third field is reserved for future use.
Comments Executable when Initiated: Yes
Coupling Group: None
*RST Condition: None
Example Querying Virtual Instrument Capability
VINS:IDEN? Queries capability.
VINStrument