User`s manual

:STOP
[SOURce:]FREQuency[1]:STOP <stop_freq> sets the stopping sample rate or
waveform frequency for a frequency-swept waveform.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<
stop_freq> numeric see below | MINimum | MAXimum Hz
The legal range for <
stop_freq>, as well as the MINimum and MAXimum values, are
context-dependent. See Coupling Rules” on page 319 for a description of the coupling
between STARt, STOP, CENTer, and SPAN.
Comments Executable when Initiated: Query form only
Coupling Group: Frequency
Related Commands: TRIGger[:STARt]:SOURce,
[SOURce:]FREQuency[1]:CENTer, MODE, RANGe, SPAN, and STARt,
[SOURce:]FUNCtion[:SHAPe], [SOURce:]ROSCillator commands
*RST Condition: SOURce:FREQuency1:STOP 10.73741824 MHz
Example Setting the Stopping Frequency
FREQ:STOP 1E3 Sets the stopping frequency to 1000 Hz.
[SOURce:]FREQuency[1]
Chapter 8 Command Reference 329