User`s manual
Comments • Use the ABORt command to prematurely halt the waveform generation and place
the trigger system in the idle state.
• Waveform output begins immediately if ARM[:STARt]:LAYer2:SOURce IMMediate
is set.
• Executing this command when [SOURce:]FUNCtion[:SHAPe] DC is set, when
[SOURce:]ARBitrary:DAC:SOURce is not set to INTernal, or the trigger system is
not in the idle state, Error -213,"Init ignored" is generated.
• Executable when Initiated: No
• Coupling Group: None
• Related Commands: *OPC, *OPC?, *RST, *WAI, ABORt, ARM subsystem,
STATus:OPC:INITiate, TRIGger subsystem
• *RST Condition: The trigger system is in the idle state.
Example Initiating Waveform Generation
INIT Initiates waveform generation.
INITiate
Chapter 8 Command Reference 307