User`s manual
• Executable when Initiated: Query form only
• Coupling Group: None
• Related Commands: ABORt, TRIGger:STOP[:IMMediate]
•
*RST Condition: ARM:STARt:LAYer1:COUNt INFinity
Example Setting Waveform Repetitions per Arm
ARM:COUN 10 Sets 10 repetitions/arm.
[:STARt]:LAYer2:COUNt
ARM[:STARt]:LAYer2:COUNt <number> specifies the number of waveform start
arms the Agilent E1445A will accept after an
INITiate:IMMediate command before
returning the trigger system to the idle state.
Parameters
Parameter
Name
Parameter
Type
Range of
Values
Default
Units
<number> numeric 1 through 65535 | MINimum |
MAXimum | 9.9E+37 | INFinity
none
MINimum selects 1 arms; MAXimum selects 65535 arms.
9.9E+37 is equivalent to INFinity.
Comments • Use the ABORt command to return the trigger system to the idle state when
ARM[:STARt]:LAYer2:COUNt set to INFinity or 9.9E+37.
• Executable when Initiated: Query form only
• Coupling Group: None
• Related Commands: ABORt, INITiate[:IMMediate]
•
*RST Condition: ARM:STARt:LAYer2:COUNt 1
Example Setting the Start Arm Count
ARM:LAY2:COUN 10 Sets 10 start arms per INITiate.
ARM