User`s manual

Frequency1
Generator Range
The [SOURce:]FREQuency[1]:RANGe command allows for higher
sample frequency operations of the USER function. This command
is only used with frequency1 generator. If set to
0 (MINimum), the
normal setting, the maximum sample frequency is the
Reference Oscillator frequency / 4
If set to MAXimum, the maximum sample frequency is the
Reference Oscillator frequency / 2
The
MAXimum setting worsens the frequency resolution by a factor
of two and introduces some sample rate jitter.
Returning the
Waveform Segment
Names
Use [SOURce:]LIST[1][:SEGMent]:CATalog? to return the names of the
different waveform segments stored in memory. The command returns
comma-separated strings that contain the names of the segment lists.
Determining the
Waveform Segment
Size
Use [SOURce:]LIST[1][:SEGMent]:VOLTage:POINts? to determine the size,
in number of waveform segments or points, of the currently selected
waveform segment.
Returning the
Segment Sequence
List Names
Use [SOURce:]LIST[1]:SSEQuence:CATalog? to return the names of the
different segment sequence lists stored in memory. The command returns
comma-separated strings that contain the names of the segment sequence lists.
Returning the
Repetition Count
List Length
Use [SOURce:]LIST[1]:SSEQuence:DWELl:COUNt:POINts? to determine
the length of the currently selected segment sequence’s repetition count list.
116 Generating Arbitrary Waveforms Chapter 3