User`s guide
Agilent E6432A Microwave Synthesizer User’s Guide 4-211
HPE6432_SetQOffsetDac
ViStatus HPE6432_SetQOffsetDac (ViSession instrumentHandle,
ViUInt16 qOffsetDac);
Purpose
This function sets a value for the Q Offset DAC.
Q Offset is used to enter an origin offset voltage for the
quadrature-phase portion of an I/Q signal. The value of Q Offset is
used to adjust out imperfections in the quadrature-phase signal.
The level of dc offset determines the level of carrier feed-through.
Factory Preset Value: 2048 (Recommended)
Parameter List
instrumentHandle
Variable Type ViSession
This is the ViSession handle that is obtained from the Initialize
function. The instrumentHandle identifies a particular instrument
session.
qOffsetDac
Variable Type ViUInt16
This parameter specifies a value for the Q Offset DAC.
Allowable values: 0 to 4095
Return Value
This parameter reports the return status of this function.
To obtain further information about the status that is returned, call the
Error Message function or refer to “Error-Code and Fail-Code
Messages” on page 3-93.
Related Topics
HPE6432_GetQOffsetDac