User manual
20 Getting Started Chapter 1
NOTE When wire jumpers JM10 through JM17 are removed, the odd-numbered
banks can no longer be connected to the analog bus. For example, if JM10
and JM11 are removed, then bank 1 can no longer be connected to the
analog bus terminals (except through user wiring).
When wire jumpers JM2 through JM5 are removed, banks 2/3 and 4/5,
respectively, can no longer be connected to the analog bus. For example,
if JM2 and JM3 are removed, then banks 2 and 3 can no longer be
connected to the analog bus terminals (except through user wiring).
Table 1-2. Jumper Configurations
* factory setting
Bank Number = Jumper
Configuration
JM Number ( 0 = Jumper, 1 = No Jumper)
Bank 0Bank 1Bank 2Bank 3123451011121314151617
1x32*1x32*1x32*1x32* -00 - -0000----
1x16 1x16 1x16 1x16 -11- -0000----
1x8 1x8 1x8 1x8 -11- -1111----
1x8 1x8 1x16 1x16 -11- - 1100----
1x16 1x16 1x8 1x8 -11- -0011----
Bank Number = Jumper
Configuration
JM Number ( 0 = Jumper, 1 = No Jumper)
Bank 4Bank 5Bank 6Bank 7123451011121314151617
1x32*1x32*1x32*1x32* ---00----0000
1x161x16 1x16 1x16 ---11----0000
1x8 1x8 1x8 1x8 ---11----1111
1x8 1x8 1x161x16 ---11----1100
1x161x16 1x8 1x8 ---11----0011