User`s manual
Connecting the Analog Bus
Figure 2-3 shows how to connect the analog bus between multiple
multiplexer modules and to the Agilent E1326A Multimeter. Use the cables
shipped with the multiplexer modules to connect the analog bus of the
multiplexer modules. Use the cable shipped with the Agilent E1326A
Multimeter to connect the analog bus of the multiplexer module to the
Multimeter input.
These cables are needed to connect the multiplexer when mounted in the
E1403 Module Carrier to the E1411A/B DMM in a C-size cardcage. They
must be ordered separately.
• Connecting E1411 to RELAY MUX’s: use E1326-61611 (long
analog bus cable).
• Connecting RELAY to RELAY or RELAY to FET MUX: use
E1400-61605.
Setting the Address Switch
The address switch (LADDR) factory setting is 112. You may have
changed the setting during module installation. Valid address values are
from 0 to 255. Refer to the "Agilent 75000 Series B System Installation and
Getting Started Guide" or the "Agilent E1406 Command Module Manual"
for addressing information. Otherwise, to change the setting, use the
following:
Chapter 2 Configuring the Agilent E1346A Multiplexer Module 21