94 Agilent E1330B Digital I/O Module Command Reference
Chapter 5
:OPERation:CONDition?
STATus:OPERation:CONDition? returns the contents of the Operation Status
Condition Register. Reading the register does not affect its contents. This command
does not affect the Agilent E1330 Digital I/O module.
:OPERation:ENABle
STATus:OPERation:ENABle <mask> specifies which bits of the associated Event
Register are included in its summary bit. The summary bit is the bit-for-bit logical
AND of the Event Register and the unmasked bit(s). This command does not affect
the Agilent E1330 Digital I/O module.
Parameters
The non-decimal numeric forms are the #H, #Q, or #B formats specified by
IEEE-488.2.
:OPERation:ENABle?
STATus:OPERation:ENABle? returns the mask set for the Operation Status
Register. This command does not affect the Agilent E1330 Digital I/O module.
:OPERation[:EVENt]?
STATus:OPERation[:EVENt]? returns the contents of the Operation Event Status
Register. Reading the register clears all bits in the register. This command does not
affect the Agilent E1330 Digital I/O module.
:PRESet
STATus:PRESet clears both the Operation Status Enable and Questionable Status
Enable Registers. This command does not affect the Agilent E1330 Digital I/O
module.
Parameter Name Parameter Type Range of Values Default
<
mask>
Numeric or
non-decimal
numeric
0 through +32767 None