User`s manual

Agilent E1330B Digital I/O Module Command Reference 87
Chapter 5
DIGital:HANDshaken:DELay
[SOURce:]DIGital:HANDshaken:DELay <time> sets the time between data valid
and the assertion of the control line to TRUE for port n. This form of the command
operates on 8-bit ports only.
Parameters
Comments :HANDshaken is the keyword used for commands relating to data
handshaking at port n. The port number n must be the last character of the
keyword without spaces.
This command sets the strobe pulse width for both input and output STRobe
handshakes.
The delay time must be set to the same value on all ports used in a multiple
port operation.
MAX sets a 15ms delay. DEF sets 2µs delay. MIN sets a delay of 0, and is illegal
for PULse and STRobe handshakes.
DIGital:HANDshaken NONE command sets the delay to 0. For all other
modes of handshaking, 2
µs is the minimum.
Specific bands of delay settings are NOT allowed. These are:
0
µs> <time> <2µs 150µs> <time> <200µs
15
µs> <time> <20µs1.5ms> <time> <2.0ms
The controller uses a rounded-up value for
<time> if these values are specified.
Related Commands: [SOURce:]DIGital:CONTroln:POLarity,
[SOURce:]DIGital:CONTroln[:VALue], [SOURce:]DIGital:FLAGn:POLarity,
[SOURce:]DIGital:HANDshaken[:MODE]
*RST Condition: Delay is set to 2 µs.
Example DIG:HAND3:DEL .005 sets the delay between the data output and the assertion of
the control line to true on 8-bit port 3 to 5 ms.
Parameter Name Parameter Type Range of Values Default
HANDshake
n
Numeric None, 0, 1, 2, or 3 None
<
time>
Numeric
2
µs to 15µs
20
µs to 150µs
200
µs to 1.5ms
2ms to 15ms
None
Discrete MIN|MAX|DEF