Error Messages 143
Appendix C
Appendix C
Error Messages
Code Message Cause
-101 Invalid character Unrecognized character in specified parameter.
-102 Syntax Error Command is missing a space or comma between parameters.
-103 Invalid separator Command parameters are not separated by a comma.
-104 Data Type Error The wrong data type (i.e. number, character, string, expression) was used
when specifying a parameter.
-108 Parameter not allowed Parameter specified in a command where none is allowed.
-109 Missing parameter No parameter specified when required.
-113 Undefined header Command header was incorrectly specified.
-124 Too many digits >257 digits were specified for a parameter.
-128 Numeric data not allowed A number was specified for a parameter when a letter is required.
-131 Invalid suffix Parameter suffix incorrectly specified.
-138 Suffix not allowed Parameter suffix is specified when one is not allowed.
-141 Invalid character data The parameter type specified is not allowed.
-161 Invalid block data Mismatch between character count in header and actual number of
characters.
-178 Expression data not allowed A parameter is enclosed in parenthesis.
-221 Settings conflict Digital I/O command settings are in conflict (e.g., control asserted when in
a handshake mode other than NONE).
-222 Data out of range Value specified is out of the legal range for parameter.
-224 Illegal Parameter Value Inconsistent parameter value or block not found.
-240 Hardware Error Hardware error detected during power-on cycle.
Return Digital I/O Module to Agilent Technologies for repair.
-410 Query Interrupted Data is not read from the output buffer before another command is issued.
-420 Query unterminated Command which generates data not able to finish executing due to a
Digital I/O Module configuration error.
-430 Query deadlocked Command execution cannot continue since the mainframe's command
input and data buffers are full. Clearing the instrument restores control.
+1000 Out of memory No memory available.
+2006 Undefined command Command not recognized by this instrument.
+2025 Invalid port number for access TYPE The port number specified is not valid for the [:type] set.
+2026 Port number out of range The port number specified is out of the legal range of port numbers.
+2027 Invalid bit number for access TYPE The bit number specified is not valid for the port [:type] set.
+2028 LW64 & LW96 not supported by this card Attempt to replace [:type] with either LW64 or LW96 keywords.
+2029 Duplicate memory block name The memory block name specified already exists.
+2030 Invalid number of bytes for TRACE
access TYPE
The number of bytes specified in a trace does not match the [:type] set.