User manual
23
Category
1
enclosure
HRU
replacement
The
HRU
has
a
mandatory
2
year
service
replacement
interval.
WARNING:
Failure
to
replace
the
HRU
after
2
years
in
service
has
elapsed
may
result
in
the
EPIRB
not
automatically
deploying
in
an
emergency.
CAUTION:
It
is
most
important
that
all
of
the
supplied
replacement
parts
are
fitted,
never
reuse
an
old
plastic
rod
or
fixing
E-clip.
Only
ever
fit
an
original
McMurdo
replacement
HRU
Kit:
Part
No.82-962-001A.
McMurdo
Breakthru
HRU,
The
kit
includes
HRU,
a
replacement
breakable
plastic
rod,
e-clip,
washer,
date
labels
and
instruction
sheet.
HRU
replacement
procedure:
1.
Remove
enclosure
R-clip
and
cover
2.
Remove
the
EPIRB,
stow
it
in
a
dry
place
It
may
activate
if
allowed
to
get
wet
3.
Hold
down
the
lever
arm
to
take
up
the
force
of
the
spring
4.
Push
the
HRU
back
then
upwards
out
of
the
slot
in
the
lever
arm
5.
When
the
rear
clip
disengages
slowly
release
the
lever
arm
6.
The
HRU
with
its
breakable
rod
can
now
be
lifted
free
and
replaced
7.
Fit
the
new
HRU
over
the
new
rod,
with
its
label
facing
outward
8.
Fit
the
replacement
washer
and
new
E-clip,
ensure
rod
moves
freely
9.
Mark
the
HRU
with
an
expiry
date
2
years
into
the
future
10.
Slide
the
HRU
into
the
slot
in
the
lever
arm
and
push
lever
arm
down
11.
Engage
rear
washer
into
back-plate
by
pushing
back
and
sliding
down
12.
Look
under
the
spring
and
check
that
the
washer
is
fully
engaged
13.
Re-Fit
the
EPIRB,
cover
and
R-clip
14.
On
side
of
cover,
remove
old
HRU
expiry
date
and
mark
new
date.
1
2
Breakable
rod
HRU
Lever
arm
Spring
Engage
washer
here
Rear
E-clip
Fitting
HRU
Washer