Technical data

62 Agilent U7232A DisplayPort Electrical Performance Compliance Test Application
7 Source Non Pre-Emphasis Level Differential Tests
Probing for Source Non Pre-Emphasis Level Differential Tests
When performing the non pre- Emphasis level differential test, the
DisplayPort Electrical Performance Compliance Test Application will
prompt you to make the proper connections. Your DisplayPort test
environment setup on the Set Up tab must match the physical connection.
Figure 19 and Figure 20 below show the differential and the single- ended
connections for Non Pre- Emphasis Level Differential Tests..
Infiniium Oscilloscope
1168A or 1169A
Probe Amplifier
N5380A SMA probe head.
Connect the plus side of the
probe to the plus side of the
SMA probe head and the
negative side of the probe to
the negative side of the SMA
probe head.
Lane on the W2641A test fixture
SMA to SMP cables
DUT
Figure 19 Probing for Differential Tests - Non Pre-Emphasis Level Tests (Single
Connection with W2641A DisplayPort Test Fixture)