9 In order to perform the equalization, you have the option to use your
own coefficient file. To do so, at the Configure page, under the Sink
Equalizer option, Select “User Defined File” from the drop down menu.
Test Plan Check Mode Turn on test plan check mode to simulate the actual test plan run flow
without actual tests being run.
SSC Acquisitions Number of SSC cycle captured for SSC related tests. Maximum
number is 25.
Low Bit Rate SSC
Smoothing Points
Sets the number of smoothing points for SSC low pass filter when bit
rate is 1.62 Gbps.
High Bit Rate SSC
Smoothing Points
Sets the number of smoothing points for SSC low pass filter when bit
rate is 2.70 Gbps.
Memory Depth Sets the memory depth for acquisition
Sink Test
Sink Mask Selects the type of mask to use for the eye test.
Sink Mask Movement This field contains 3 options. (1) Find Passing Mode will automatically
search +/-0.5UI horizontally until no violation occurs, (2) Fixed Mask
will not be moving, it only reports Pass or Fail upon test, (3) Find
Biggest Margin will search +/-0.5UI horizontally to find the maximum
margin of non-violation mask.
Sink Equalizer Selects the type of equalization to use for the Sink test. Select Manual
if you would like to provide own Equalization Coefficient file.
Sink Data Rate
Measurement
Specify the method to measure data rate on waveform. User can
specifically enter the data rate by themselves.
Jitter Separation Edges Sets the number of edges measured for the jitter separation test.
Bit Error Rate Sets the bit error rate for the RJ/DJ measurements.
Table 23 Test Configuration Options
Configuration Option Description