Technical data
82 U7232A DisplayPort Compliance Testing Notes
9 Source Frequency Accuracy Tests
Probing for Frequency Accuracy Tests
When performing the frequency accuracy test, the DisplayPort Electrical
Performance Compliance Test Application will prompt you to make the
proper connections. Your DisplayPort test environment setup on the Set
Up tab must match the physical connection. There are two modes that you
can use to configure the Set Up tab: Wizard Mode and Manual Mode. The
Wizard Mode leads you step by step through each of the different setup
choices with a description of what the choices do. The Manual Mode
allows you to choose only those set up choices that you want to make
without going through every possible choice of settings.
For example, if your test environment setup is similar to Figure 29 below:
two Connection by using W2641A Test Fixture, then your physical
connection for the frequency accuracy test should be similar to Figure 30.
W2641A
Figure 29 Setup for Frequency Accuracy Differential Tests (Two Connections with
W2641A DisplayPort Test Fixture)