42 U7232A DisplayPort Compliance Testing Notes
5 Source Non-ISI Jitter Tests
Probing for Non-ISI Jitter Test
When performing the non- ISI jitter test, the DisplayPort Electrical
Performance Compliance Test Application will prompt you to make the
proper connections. Your DisplayPort test environment setup on the Set
Up tab must match the physical connection. There are two modes that you
can use to configure the Set Up tab: Wizard Mode and Manual Mode. The
Wizard Mode leads you step by step through each of the different setup
choices with a description of what the choices do. The Manual Mode
allows you to choose only those set up choices that you want to make
without going through every possible choice of settings.
For example, if your test environment setup is similar to Figure 13: one
Connection using the W2641A DisplayPort Parametric Test Fixture, 1168A
or 1169A differential probe with N5380A SMA probe head then your
physical connection for the jitter test should be similar to Figure 14.
Figure 14 and Figure 15 below show the single- ended and differential
connections for Non- ISI Jitter Tests.
Figure 13 Setup for Non-ISI Jitter Test (1 Connection with W2641A DisplayPort
Parametric Test Fixture)