Technical data

Source Eye Diagram Testing 3
U7232A DisplayPort Compliance Testing Notes 29
PASS Condition
The following table and figure define the mask for the eye measurements.
There can be no signal trajectories entering into the mask. Table 2 shows
the voltage and time coordinates for the mask used for the eye diagram.
Spread Spectrum Clock (SSC)
SSC Acquisitions Sets the number of acquisitions taken to verify the SSC.
Single-ended Tests
Rise-Fall Mismatch
Rise-Fall Mismatch Edge Sets the number of edges measured for the rise-fall mismatch test.
Upper Threshold (Debug
only)
Sets the upper threshold used to make a rise time or fall time
measurement.
Lower Threshold (Debug
only)
Sets the lower threshold used to make a rise time or fall time
measurement.
Intra-pair Skew
Intra-pair Edge Sets the number of edges measured for the intra-pair skew test.
AC Common Mode
AC Common Edge Sets the number of edges measured for the AC common mode test.
Table 1 Test Configuration Options
Configuration Option Description