Technical data
24 U7232A DisplayPort Compliance Testing Notes
3 Source Eye Diagram Testing
.
You can use any of the oscilloscope channel and connect them to any of
the lane test points. You select the channels used for test a lane in the Set
Up tab of the DisplayPort Electrical Performance Compliance Test
Application.
The data lanes and channels shown in the previous figures are just
examples. You can choose any desired data lane and channel that you
want.
For more information on the 1168A or 1169A probe amplifiers and
differential probe heads, see Chapter 15, “InfiniiMax Probing,” starting on
page 147.
Infiniium Oscilloscope
Data Channel
SMA to SMP cables
DUT
Lane on the W2641A test fixture
Figure 6 Probing for Single-ended Tests - Data Eye Pattern Tests using the W2641A