User manual

User Manual: Agilent Acqiris 10-bit Digitizers Page 6 of 27
1.4. Model Names
Agilent Technologies Inc. acquired Acqiris SA and its product lines in December 2006. Use the tables below to cross
reference the legacy model name and new Agilent numbers. The legacy model name is what is used in the Acqiris
applications and the API.
Agilent Model Number
U1062A-001
U1062A-002-2F5
U1062A-002-2FZ
U1065A-001-FHF
U1065A-001-F50
U1065A-002-F50
U1065A-002-FHF
U1065A-004-F50
U1065A-004-FHZ
1.5. Disclaimer and Safety
The 10-bit DC Series CompactPCI/PXI digitizers have been designed to operate inside a CompactPCI/PXI crate. The
crate provides the modules with all needed power. Agilent does not recommend operation of the DC Series modules
outside of a CompactPCI/PXI crate.
CAUTION: Do not exceed the maximum input voltage rating! The maximum input voltage for 50
input
impedance is
±
5 V. The maximum input for 1 M
input impedance is
±
300 V (dc + ac).
1.6. Warning Regarding Medical Use
The Digitizer cards are not designed with components and testing procedures that would ensure a level of reliability
suitable for use in treatment and diagnosis of humans. Applications of these cards involving medical or clinical
treatment can create a potential for accidental injury caused by product failure, or by errors on the part of the user.
These cards are not intended to be a substitute for any form of established process or equipment used to monitor or
safeguard human health and safety in medical treatment.
WARNING: The modules discussed in this manual have not been designed for making direct measurements
on the human body. Users who connect an Acqiris module to a human body do so at their own
risk.
1.7. Packaging and Handling
Your Digitizer is shipped with the following components:
A compact disc in an Agilent Technologies paper CD envelope that includes
o 10 product User Manuals in electronic form (8-bit Digitizers, 10-bit Digitizers, 12-bit Digitizers,
Averagers, Analyzers, Signal Analyzers, Streamer Analyzers, Time-to-Digital Converters, 3-, 5-,
and 8-slot CompactPCI Crates, and the 21-slot CompactPCI Crate),
o 1 Programmer’s Guide and 1 Programmer’s Reference Manual,
o device drivers with sample software for different operating systems, environments and languages,
o the Analyzer Demo application, a demonstration program for the AC/SC Analyzer products,
o the AcqirisLive application, a demonstration program for our digitizer and averager products,
o the SSR Demo application, a demonstration program for the Acqiris AP235/AP240 Analyzers,
o the APX01 Demo application, a demonstration program for the Acqiris AP101/AP201 Analyzers,
o the TC Demo application, a demonstration program for the Acqiris TC840/TC842/TC890 Time-to-
Digital Converters,
o full installation procedures for use with Microsoft Windows, National Instruments LabVIEW RT,
Wind River VxWorks, IVI-COM/C, and Linux software.