Specifications

18
dataTec ▪ Ferdinand-Lassalle-Str. 52 ▪ 72770 Reutlingen ▪ Tel. 07121 / 51 50 50 ▪ Fax 07121 / 51 50 10 ▪ info@datatec.de ▪ www.datatec.de
Up to 110 MHz (4-Terminal Pair) Other Components
16089A Large Kelvin Clip Leads
Terminal Connector:
4-Terminal Pair, BNC
DUT Connection: 4-Terminal
Cable Length (approx.):
0.94m (from connector to clip's tip)
Weight (approx.): 300 g
Additional Error: The additional error is negligible
when compared to the instrument's accuracy.
Description: This test fixture makes it possible to measure odd-
shaped components that cannot be measured with conventional fix-
tures. It is equipped with two insulated Kelvin clips.
Applicable Instruments:4263B4268A*4284A*4285A4288A*
4294AE4980AE4981A**
*denotestheinstrumentisobsolete.
**applicableinalimitedreuencyrange.
Frequency: 5 Hz to 100 kHz
Maximum Voltage: ±42 V peak max. (AC+DC)
Operating Temperature: 0°C to 55°C
DUT Size:
See figure below
Furnished Accessories:
Compensation and Measurement: Open and short compensations
are recommended before measurement. For open compensation, do
not connect the Kelvin clips to anything. Short compensation is per-
formed by holding a shorting plate with the Kelvin clips. After per-
forming open and short compensations, the DUT is held with the
Kelvin clips.
16089B Medium
Kelvin Clip Leads
Terminal Connector: 4-Terminal Pair, BNC
DUT Connection: 4-Terminal
Cable Length (approx.):
0.94m (from connector to clip's tip)
Weight (approx.): 300 g
Additional Error: The additional error is
negligible when compared to the instrument's
accuracy.
Description: This test fixture makes it possible to measure odd-
shaped components that cannot be measured with conventional fix-
tures. It is equipped with two insulated Kelvin clips.
Applicable Instruments:4263B4268A*4284A*4285A4288A*
4294AE4980AE4981A**
*denotestheinstrumentisobsolete.
**applicableinalimitedreuencyrange.
Frequency: 5 Hz to 100 kHz
Maximum Voltage: ±42 V peak max. (AC+DC)
Operating Temperature: 0°C to 55°C
DUT Size: See figure below
Furnished Accessories:
Compensation and Measurement: Open and short compensations
are recommended before measurement. For open compensation, do
not connect the Kelvin clips to anything. Short compensation is per-
formed by connecting the Kelvin clips together. After performing
open and short compensations, the DUT is held with the Kelvin clips.
18
Description P/N Qty.
Operating and Service Manual 16089-90020 1
Description P/N Qty.
Operating and Service Manual 16089-90020 1