User`s manual

Installing the
E1406A Command
Module
Use the following procedure to install the Agilent E1406A Command
Module into slot 1 (when the V743 controller is installed in slot 0).
1. If the mainframe is on, turn it off.
2. Insert the Command Module into the mainframe by aligning the top
and bottom of the card with the card guides inside the mainframe.
Slowly push the module straight into the slot until it touches the
backplane connectors.
3. Push in the extraction levers to seat the module into the mainframe.
4. Tighten the retaining screws on the top and bottom edges of the
Command Module front panel.
Top Rail
Retaining
screws
Bottom rail
Install module in
slot 1
E1406A Command Module
Extraction
levers
Figure 2-37. Installing the E1406A with the V743
2-44 Setting Up an Embedded V743 Controller C-Size Configuration Guide