User`s manual
Error Message Cause
24 INTERRUPT LINE UNAVAILABLE The interrupt line assigned by the user-defined interrupt line
table is not available. Either the line has been assigned or
has been reserved. This error also occurs if the line being
assigned to an interrupter is not handled by the interrupter’s
commander.
25 INVALID UDEF HANDLER A user-defined interrupt handler specified in the interrupt line
allocation table is invalid. The handler logical address may
not be valid, the device may not be a programmable
handler, or the device has been assigned as many lines as it
can handle.
26 INVALID UDEF INTERRUPTER A user-defined interrupter specified in the interrupt line
allocation table is not a valid interrupter. The interrupter
logical address may not be valid, the device may not be a
programmable interrupter, or the device has been assigned
as many lines as it can interrupt on.
WARNING DIAGNOSTIC MODE ON The diagnostic switch on the Command Module is set to ’1’.
Only the system instrument is started. No other modules
receive BNO.
WARNING RESOURCE MANAGER NOT IN SLOT
0
The Command Module is the resource manager ( logical
address = 0) but is not installed in slot 0. The Command
Module will configure the system but will not do dynamic
configuration.
WARNING SYSFAIL DETECTED SYSFAIL occurred during operation. The resource manager
re-boots.
30 PSEUDO INSTRUMENT LADD
UNAVAILABLE
The logical address requested by a pseudo instrument (e.g.
IBASIC) is already in use. Pseudo devices request a
particular logical address. This error occurs if the logical
address is used by a static or dynamically configured device.
31 FILE SYSTEM START UP FAILED There is not enough memory in the Command Module to set
up the file system required for IBASIC.
32 INACCESSIBLE A32 MEMORY An A32 device has memory below 20000000 or above
DFFFFFFF. The Command Module can assign, but cannot
access A32 memory.
33 INVALID UDEF MEMORY BLOCK The base address specified in the A24/A32 address
allocation table is invalid, or the address block exceeds
FFFFFFh in A24 memory.
34 UDEF MEMORY BLOCK
UNAVAILABLE
The memory block specified in the A24/A32 address
allocation table has already been assigned. Also, in a
system with VXI-MXI VXIbus extenders, A24/A32 window
restrictions may force some addresses to unavailable on a
given VMEbus.
35 INVALID UDEF ADDRESS SPACE An invalid A24/A32 address space specifier was used in the
A24/A32 address allocation table.
36 DUPLICATE UDEF MEMORY LADD A logical address is specified more than once in the same
A24/A32 address allocation table.
37 INVALID UDEF CNFG TABLE The valid flag in the user-defined commander/servant
hierarchy table is not true (1). VXI:CONF:CTAB <address>
has been set but is pointing to an invalid table. Either the
table is corrupt or has not been downloaded.
Table 1. Command Module Resource Manager Configuration Errors (Cont’d)
B-4 Configuration and Start-up Errors C-Size Configuration Guide