User`s manual
Error Message Cause
13 LADD OR IACK SWITCH SET WRONG Either a device logical address is set incorrectly, or the
interrupt switches on the mainframe backplane are set
incorrectly.
14 INVALID UDEF SECONDARY
ADDRESS
Invalid user-defined secondary address specified in the
commander/servant hierarchy table.The secondary address
specified was not 0 - 30, the address was 0 which is the
Command Module address, or the module is not in the
servant area of the Command Module.
15 DUPLICATE SECONDARY ADDRESS The same secondary address was specified for more than
one module in the user-defined commander/servant
hierarchy table.
16 INVALID SERVANT AREA The servant area of a commander is greater than 255, or the
servant area of a servant module is greater than that of its
commander. An invalid servant area is truncated to an
allowable range and system configuration continues.
17 SLOT 0 FUNCTIONS DISABLED The Command Module is installed in slot 0 and its Slot 0 and
System Controller switches are set to ’Disable’.
18 INVALID COMMANDER LADD The commander specified in the user-defined
commander/servant hierarchy table is not a valid
message-based commander, or the device does not exist.
19 BNO FAILED BNO was issued to a message-based device whose
response indicated an error condition. The Begin Normal
Operation command may have failed or the device returned
a response other than FFFEh. (See the VXI specification for
a description of the BNO response.)
20 WRITE READY TIMEOUT The Command Module timed out waiting for write ready to
be asserted by a message-based device. The Command
Module/resource manager was attempting to send a word
serial command to a message-based device but write ready
was not asserted on the device within 60 seconds. This can
occur either before or after the command was sent. If before,
the Command Module timed out without sending the
command. If after, the Command Module timed out while
determining if ERR* was asserted by the message-based
device.
21 READ READY TIMEOUT The Command Module timed out waiting for read ready to
be asserted by a message-based device. The Command
Module was attempting to read the response to a
message-based query command, but read ready was not
asserted on the device within 60 seconds.
22 ERR* ASSERTED A word serial protocol error occurred. The Command
Module/resource manager detected a word serial protocol
violation due to a word serial command. The Command
Module checks for ERR* asserted before and after sending
a word serial command to a message-based device. If
ERR* is asserted before, the command is not sent. This
error also occurs if the Command Module is not the resource
manager and it receives a word serial command it does not
recognize.
23 ENO FAILED ENO was issued to a message-based device whose
response indicated an error condition. Proper ending of
normal operation is the response FFFEh.
Table 1. Command Module Resource Manager Configuration Errors (Cont’d)
C-Size Configuration Guide Configuration and Start-up Errors B-3