User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

10-76 Agilent B1500 User’s Guide, Edition 7
Application Library and Utilities
Desktop EasyEXPERT
Advanced Setup Differences on Advanced Setup
• Series R always shows NONE.
• Wait Time Control is not supplied.
Restrictions for
Standard Edition
There are the following restrictions for the Desktop EasyEXPERT Standard edition.
• I/V-t Sampling classic test is not supported.
• VSU, VMU, and PGU are not supported.
• Agilent E5250A Switching Matrix is not supported.
Table 10-17 Setting of High Resolution ADC
NOTE To reuse the test setup for B1500A
Perform the following procedure to reuse the test setup created for the B1500A.
1. Launch Desktop EasyEXPERT with the condition Set Analyzer=B1500A.
2. Export the test setups to be reused. And exit Desktop EasyEXPERT.
3. Launch Desktop EasyEXPERT with the condition Set Analyzer=4155B, 4156B,
4155C, or 4156C.
4. Import the test setups exported at the step 2.
5. Set the channel for the analyzer to use.
Also, the procedure made by replacing the step 1 with the step 3 can be used to reuse
the test setup created for the 4155/4156.
Mode Factor Setting of 4155/4156
AUTO - MEDIUM
MANUAL 1 ≤ N ≤ 127 SHORT, TIME=80 μs × N
PLC 1 MEDIUM
N ≥ 2LONG, NPLC=N