User`s guide
Table Of Contents
- User’s Guide
- 1 Getting Started
- 2 Introduction
- 3 Installation
- 4 Using EasyEXPERT
- 5 Classic Test Definition
- I/V Sweep
- Multi Channel I/V Sweep
- I/V List Sweep
- I/V-t Sampling
- C-V Sweep
- Direct Control
- Function Setup
- Auto Analysis Setup
- Display Setup
- SMU Range Setup Window
- ADC and Integration Time Setup Window
- Advanced Setup Window
- CMU Range Setup Window
- Advanced Setup Window for C-V Sweep
- Switching Matrix Control
- SPGU Control
- SPGU Pulse Setup Window
- Load Z Setup Window
- Pulse Switch Setup Window
- SPGU ALWG Setup Window
- Define ALWG Waveform Window
- 6 Application Test Definition
- 7 Function Details
- I/V Sweep Measurement
- Multi Channel I/V Sweep Measurement
- I/V-t Sampling Measurement
- C-V Sweep Measurement
- SPGU Module
- Sweep Abort Function
- Standby Function
- Bias Hold Function
- Current Offset Cancel
- SMU CMU Unify Unit
- Atto Sense and Switch Unit
- SMU/PG Selector
- SMU Ranging Mode
- SMU Compliance
- SMU Pulse
- SMU Measurement Time
- SMU Filter
- SMU Series Resistor
- Interlock Function
- Auto Power Off Function
- Initial Settings
- 8 Built-in Programming Tool
- 9 If You Have a Problem
- When You Operate B1500A
- When You Perform Measurement
- Measurement Takes More Time than Specified
- Noise Affects the Measured Values
- Voltage Measurement Error is Large
- SMU Oscillates for High-Frequency Device Measurements
- SMU Oscillates for Negative Resistance Measurements
- Large Current Causes High Temperature (Thermal Drift)
- Measurement Damages the Device under Test
- Leaving Connections Damages Devices after Measurement
- Unexpected Sampling Measurement Data is Returned
- MFCMU Causes Unbalance Condition
- Before Shipping to Service Center
- Data Backup and Recovery
- B1500A System Recovery
- Updating EasyEXPERT
- Error Codes
- 10 Application Library and Utilities

10-74 Agilent B1500 User’s Guide, Edition 7
Application Library and Utilities
Desktop EasyEXPERT
Using 4155B/4156B/4155C/4156C
This section describes the notices when using Desktop EasyEXPERT and
4155/4156.
4155/4156
Firmware Revision
4155/4156 firmware revision supported by Desktop EasyEXPERT
• HOSTC: 03.08 or later
• SMUC: 04.08 or later
4155/4156
Functions
4155/4156 functions unsupported by Desktop EasyEXPERT
• Log sampling measurement and Thinned out sampling measurement
• Functions using R Box
• Differential voltage measurement using VMU (Voltage Monitor Unit)
• DC bias output using PGU (Pulse Generator Unit)
• Other functions unavailable for the B1500A
Desktop
EasyEXPERT
Classic tests available for 4155/4156
• I/V Sweep, I/V-t Sampling, and Switching Matrix Control for 4155C/4156C
• I/V Sweep and Switching Matrix Control for 4155B/4156B
Desktop EasyEXPERT functions unavailable for 4155/4156
• Functions using SMU Series Resistor
• Functions using ASU (Atto Sense Unit)
• Functions using SCUU (SMU CMU Unify Unit)
• Functions using CMU (Capacitance Measurement Unit)
• Functions using SPGU (Semiconductor Pulse Generator Unit)
PGU can be used instead of SPGU for the I/V Sweep and I/V-t Sampling classic
tests. The Load Z function and the ALWG output are not supported. The Output
Impedance dialog box is available to set the output impedance of the PGU.
• Functions using WGFMU (Waveform Generator/Fast Measurement Unit) and
RSU (Remote-sense and Switch Unit)